How to Navigate the Chiller Touch Panel and Settings (1 HP & 1.5 HP Models)Updated 2 hours ago
The Arctic Warriors 1 HP and 1.5 HP chillers are equipped with a built in touch control panel that allows you to manage temperature, operating modes, ozone sanitation, timers, and WiFi setup. This guide explains what each button does and how to use every setting correctly based on the official user manual.
1. Power Button
Function: Turns the chiller ON or OFF.
How to use
- Press once to turn the unit ON
- Press again to turn the unit OFF
The logo on the display will remain illuminated when the unit is powered on.
2. Lock and Unlock Function
Function: Prevents accidental changes to settings.
How to use
- Press and hold the Lock button for 3 seconds
- Repeat the same action to unlock
When locked, other buttons will not respond until unlocked.
3. Settings Button
Function: Accesses system settings.
Inside the settings menu you can
- switch temperature units between Celsius and Fahrenheit
- set the system time and date
- adjust internal parameters
This menu is used mainly for configuration rather than daily operation.
4. Cooling Mode Button
Function: Activates cooling mode.
How it works
- Press the Cooling button to enable active cooling
- The chiller will cool water until it reaches the target temperature
- Once reached, the system maintains the temperature automatically
Cooling mode is used for normal cold plunge operation.
5. Heating Mode Button
Function: Activates heating mode if supported by your unit.
How it works
- Press the Heating button to enable heating
- The unit will warm the water to the target temperature
Not all configurations use heating. Availability depends on your model and setup.
6. Temperature Adjustment Controls
Function: Sets your target water temperature.
How to adjust
- Use the Up and Down arrows on the control panel
- Or drag the adjustment bar in the app
The display shows
- current water temperature
- target temperature
The lowest supported temperature is typically 3°C according to the manual.
7. Ozone Button (O₃)
Function: Controls ozone sanitation.
Press the Ozone button to adjust ozone settings.
Default ozone behavior
- ozone starts 2 minutes after the chiller powers on
- ozone runs for 90 seconds per cycle
- ozone rests for 1800 seconds between cycles
- ozone intensity is preset internally
Ozone helps keep water clean and reduce bacteria without chemicals.
8. Timer Button (Scheduled On and Off)
Function: Schedules automatic power on and off times.
How to use
- Press the Timer button
- Enable the timer
- Set on and off times
- The system supports up to 4 timer schedules
Timers are useful for maintaining temperature automatically.
9. WiFi Button
Function: Enables WiFi pairing mode.
How to use
- Press the WiFi button briefly
- The unit enters network configuration mode
- Open the Smart Life app to complete pairing
The chiller supports 2.4 GHz WiFi only.
10. Temperature Unit Switch
Function: Switches between Celsius and Fahrenheit.
How to use
- Press Settings
- Select Temperature Type
- Choose °C or °F
The display updates instantly after selection.
11. Fault Alarm Indicator
Function: Displays system errors.
When a fault occurs
- the fault icon flashes on the display
- press the flashing icon to view error details
- follow the on screen instructions
You can scan the QR code shown for repair videos and explanations.
12. Current Temperature Display
The screen shows
- current water temperature
- current operating mode
- current system time
This information updates automatically during operation.
When to Contact Support
Contact support if
- the touch panel does not respond
- buttons stop working
- fault codes continue to appear
- temperature does not change as expected
- WiFi pairing fails repeatedly
Email: [email protected]
Phone: (386) 388-6867
Summary
The touch panel allows you to
- power the unit on and off
- lock and unlock controls
- set water temperature
- activate cooling or heating
- control ozone sanitation
- schedule timers
- connect to WiFi
- monitor system status
Understanding these controls ensures safe operation and optimal performance of your Arctic Warriors 1 HP and 1.5 HP chillers.